Configure the value of PTP Sync message interval time to send Sync event message to the slaves when the port is in the master state.
boundary |
Boundary clock instance. |
ordinary |
Ordinary clock instance. |
sync-interval |
Time between successive sync messages. |
seconds_log_base_2 |
The log base 2 value of the seconds of the timeout for PTP announce messages. For example, to specify 2 seconds, use 1. The default value is -6, and the range is -7 to 1. |
vlan_name |
VLAN name to which the command is to be applied. |
The default value of the seconds_log_base_2 parameter is -6.
Use this command to configure the announce message rate on the clock port. The clock port should not have unicast static slaves or masters added for this configuration to be applied.
This command is available only for boundary and ordinary clocks.
The following command configures the sync message rate of 2/second on the clock port lpbk-gm of the boundary clock:
# configure network-clock ptp boundary sync-interval -1 vlan lpbk-gm
The following command configures the sync message rate of 8/second on the clock port lpbk-gm of the ordinary clock:
# configure network-clock ptp ordinary sync-interval -3 vlan lpbk-gm
This command was first available in ExtremeXOS 15.1.
This command is available on 7520-48Y and 7720 platforms.
Note
PTP commands can be used only with the Premier license pack.